- frigotech
An air handling unit is a technical component designed for heating, cooling, humidifying or dehumidifying commercial or industrial premises. It is an all-air system with constant or variable flow.
An AHU is either a monobloc type or consists of modules added together, depending on the configuration, such as ventilation modules, cold and hot coil modules, filter modules, etc.
There are two types of air handling units:
– Single-flow AHUs, which are either all fresh air, all return air, or a mixture of both flows.
– Dual-flow AHUs, which allow for all possible combinations of return air, fresh air, exhaust air, and treated air, depending on the configuration.
Details of a single-flow air handling unit


At Frigotech, we offer our customers a wide selection of highly economical and high-performance appliances.
To better satisfy our customers, we only work with the best brands on the European market, including Cairox, Ciat, Carrier and Daikin. This allows us to guarantee reliable, optimal and efficient ventilation with low electricity consumption.
Our design and calculation office develops fully customised ventilation systems that perfectly meet your requirements.
Components of a single-flow air handling unit:
Fresh air intake (Fresh air damper + Fresh air sensor)
Outside air enters through the motorised fresh air vent, which is controlled according to requirements. A sensor measures the temperature of the incoming air.
Mixing chamber (if applicable)
In sommige eenvoudige configuraties is er geen mengkamer. Als er echter wel een mengkamer aanwezig is, kan deze worden gebruikt om een mengsel van verse lucht en retourlucht te doseren om het energieverbruik te optimaliseren.
Filtration
The air flows through filters (usually G4 + F7 or M5 + F7), which remove particles, dust and pollen. A filter switch monitors the level of contamination.
Treatment batteries (heating and/or cooling)
Two batteries are powered:
🔴 Warme batterij (V3V warm): verwarmt de lucht volgens de instelling.
🔵 Cold battery (V3V cold): used in summer to cool the air.
The antifreeze thermostat protects the warm battery from freezing.
Fire hatch (safety)
It cuts off the air supply in the event of a fire being detected.
Drip guard
Protects the fan by stopping any condensation that may be present after the cooling coil.
Blower fan (EC motor)
It propels the treated air into the premises. The EC (electronically commutated) motor offers good efficiency and precise speed variation.
The ventilation pressure switch detects a loss of pressure or a fan stoppage.
Blow probe
It controls the temperature of the blown air.
Smoke detector
Automatically shuts down the AHU if smoke is detected.
Automation / Control
Manages instructions, shutter opening, temperature, anomaly detection, alarms (clogged filter, antifreeze, motor fault, etc.).
General operation:
Fresh air is drawn in, filtered, heated or cooled if necessary, and then blown into the rooms to be ventilated. This is a single-flow system, meaning that it blows in fresh air without mechanical extraction. Stale air is removed naturally (through extraction grilles or openings) or by a separate system.
Selecting an air handling unit (AHU) suited to your requirements
Before selecting an air handling unit, it is essential to understand the two main categories available on the market:
Single-flow CTAs: these manage a single air flow, whether it is incoming air, outgoing air, or sometimes a mixture of both.
Dual-flow CTAs: these systems allow both the injection of fresh outside air and the extraction of stale indoor air. They generally incorporate a heat recovery system, allowing energy from the extracted air to be transferred to the incoming fresh air.
Furthermore, the operation of a CTA can vary according to several modes:
cooling only mode,
mainly cold weather,
balanced hot/cold mode,
mainly warm weather.
Air handling units are widely used in professional environments such as hospitals, industrial sites, hotels and shopping centres. They are often custom-designed to control the temperature, air flow and humidity inside buildings, while ensuring optimal air quality. These installations play a crucial role in the rapid removal of pollutants, including VOCs (volatile organic compounds), gases and other harmful particles.
In sectors where activities generate significant pollutant emissions, it is essential to opt for a dual-flow AHU in order to comply with current regulations on indoor air quality.
Define your needs clearly to make the right choice
The choice between a single-flow and dual-flow AHU is based on a detailed analysis of your actual needs. This step is crucial for:
Determine the air flow rates required for proper air renewal.
Plan a consistent investment budget,
Above all, choose energy-efficient equipment.
Indeed, an energy-efficient air handling unit will not only improve thermal and sanitary comfort, but also reduce your long-term operating costs.
Trust in Frigotec's expertise
Installing an air handling unit is a major project. It is therefore strongly recommended that you seek the assistance of a specialist.
Frigotec offers customised solutions for heating, ventilation, air conditioning (HVAC) and air treatment, suitable for all types of establishments: factories, supermarkets, shops, offices, hotels and restaurants, banks and even theatres.
Do you have a project or need technical advice? Please do not hesitate to contact Frigotec. Our teams are at your disposal to help you set up a reliable, high-performance installation that complies with current energy standards.
SERVICE DE QUALITÉ
Choisir Frigotech c’est choisir la qualité, la rapidité et la fiabilité !
RAPIDITÉ
Nos techniciens se déplaceront et analyseront rapidement la situation afin d’effectuer tout le nécessaire pour votre installation.
+10 ANS D’EXPERIENCE
Laissez-nous utiliser nos 10 ans d’expérience afin de vous aider à trouver la solution idéale à votre besoin.
Disponible 24h/24 et 7j/7
Notre service de dépannage est joignable 7/7j 24/24h.
- INTERESTED IN OUR SERVICES?
Contact Us for a
Free Quote!
Free Quote!
Do you have a refrigeration equipment installation project? Would you like more information about our services? Contact us, we will be happy to help!
- frigotech
Our Office
Address:
- 209 Avenue Louise, Box 7, 1050 Brussels, Belgium
Contact:
Emergency repair service:
Opening hours:
- Monday–Friday: 8:00 a.m.–7:00 p.m.
- Saturday: 8:00 a.m. to 2:00 p.m.
- Sunday: Closed
- frigotech
They're Talking About Us!
Alain Van Wel
Bonjour, j’ai fait appel à Frigotech pour une installation d’une chambre froide pour mon restaurant. Parmi les sociétés que j’ai contactées, Frigotech m’a le plus intéressée au niveau qualité/prix. Tout s’est bien passé, hyper rapide et efficace. Merci encore !
Louise Martin
Nous tenons à remercier le professionnalisme de Frigotech. Nous avons fait appel à leur services pour installer une pompe à chaleur air-eau. Les techniciens ont été patients et efficaces face à mes innombrables questions 😊. Travail parfait et effectué à temps.
Marianne & Bernard Laruelle-DeDecker
Frigotech a effectué l’installation de notre climatisation, j’ai été agréablement surpris quant à leur réactivité, leur attention à notre égard ainsi qu’à leur professionnalisme. Les techniciens nous ont expliqué pas à pas tous les détails de l’installation. Ils sont ponctuels et répondent à la moindre de nos questions. Je conseille vivement la société Frigotech !
Thibaut Lemaître-Maréchal
J’ai trouvé la société de référence pour installer une ventilation double flux pour mon domicile ! On s’y sent tellement mieux et l’air est plus purifié. Equipe au top et installation rapide et propre
All products come with a 2-year warranty.
We guarantee that our products comply with your order and meet the normal expectations you may have, taking into account the product specifications. We also guarantee that our products comply with all laws in force at the time of your order.
This post is also available in: Dutch French
frigotec
NOTRE ZONE D'INTERVENTION
Climatisation
Dépannage climatisation habitation Bruxelles
Climatisation maison
Installateur airco à Bruxelles
Réfrigération
Frigo comptoir
Chambre froide
Dépannage chambre froide Bruxelles
Vitrine réfrigérée
Chiller producteur d’eau glacée/glycolée
Frigo armoire
Ventilation
Centrale de traitement d’air (CTA)
Déshumidificateur
Ventilation extraction
Vmc double flux – simple flux
Pompe à chaleur
Pompe à chaleur air-eau
Pompe à chaleur air-air
Pompe à chaleur eau-eau
Réparation pompe a chaleur
Installation chauffe-eau thermodynamique
Chauffage
Installation chaudière à Bruxelles
Dépannage chaudière Bruxelles
Entretien chaudière Bruxelles
Chauffagiste à Ixelles
Chauffagiste à Uccle
Chauffagiste à Jette
Chauffagiste à Forest
Chauffagiste à Evere
Chauffagiste à Auderghem
Chauffagiste à Saint gilles
Chauffagiste à Schaerbeek
A propos
Frigotech est une entreprise spécialisée dans : la réfrigération industrielle et commerciale, Climatisation et Ventilation. Agréé par Bruxelles environnement
Contact
SOS dépannage urgent (7/7j 24/24h)
Horaires
Lundi-Vendredi: 8:00-19:00
Samedi: 8:00-14:00
Dimanche: fermée
Liens Utiles
GARANTIE 2 ANS
Tous les produits bénéficient d’une garantie de 2 ans. Nous garantissons que nos produits sont conformes à votre commande.
